756 research outputs found

    An intuitive tangible game controller

    Get PDF
    This paper outlines the development of a sensory feedback device providing a low cost, versatile and intuitive interface for controlling digital environments, in this example a flight simulator. Gesture based input allows for a more immersive experience, so rather than making the user feel like they are controlling an aircraft the intuitive interface allows the user to become the aircraft that is controlled by the movements of the user's hand. The movements are designed to feel intuitive and allow for a sense of immersion that would be difficult to achieve with an alternative interface. In this example the user's hand can become the aircraft much the same way that a child would imagine it

    Acquisition of sensorimotor fMRI under general anaesthesia: Assessment of feasibility, the BOLD response and clinical utility

    Get PDF
    We evaluated whether task-related fMRI (functional magnetic resonance imaging) BOLD (blood oxygenation level dependent) activation could be acquired under conventional anaesthesia at a depth enabling neurosurgery in five patients with supratentorial gliomas. Within a 1.5 T MRI operating room immediately prior to neurosurgery, a passive finger flexion sensorimotor paradigm was performed on each hand with the patients awake, and then immediately after the induction and maintenance of combined sevoflurane and propofol general anaesthesia. The depth of surgical anaesthesia was measured and confirmed with an EEG-derived technique, the Bispectral Index (BIS). The magnitude of the task-related BOLD response and BOLD sensitivity under anaesthesia were determined. The fMRI data were assessed by three fMRI expert observers who rated each activation map for somatotopy and usefulness for radiological neurosurgical guidance. The mean magnitudes of the task-related BOLD response under a BIS measured depth of surgical general anaesthesia were 25% (tumour affected hemisphere) and 22% (tumour free hemisphere) of the respective awake values. BOLD sensitivity under anaesthesia ranged from 7% to 83% compared to the awake state. Despite these reductions, somatotopic BOLD activation was observed in the sensorimotor cortex in all ten data acquisitions surpassing statistical thresholds of at least p < 0.001uncorr. All ten fMRI activation datasets were scored to be useful for radiological neurosurgical guidance. Passive task-related sensorimotor fMRI acquired in neurosurgical patients under multi-pharmacological general anaesthesia is reproducible and yields clinically useful activation maps. These results demonstrate the feasibility of the technique and its potential value if applied intra-operatively. Additionally these methods may enable fMRI investigations in patients unable to perform or lie still for awake paradigms, such as young children, claustrophobic patients and those with movement disorders

    Multimodal augmented reality tangible gaming

    Get PDF
    This paper presents tangible augmented reality gaming environment that can be used to enhance entertainment using a multimodal tracking interface. Players can interact using different combinations between a pinch glove, a Wiimote, a six-degrees-of-freedom tracker, through tangible ways as well as through I/O controls. Two tabletop augmented reality games have been designed and implemented including a racing game and a pile game. The goal of the augmented reality racing game is to start the car and move around the track without colliding with either the wall or the objects that exist in the gaming arena. Initial evaluation results showed that multimodal-based interaction games can be beneficial in gaming. Based on these results, an augmented reality pile game was implemented with goal of completing a circuit of pipes (from a starting point to an end point on a grid). Initial evaluation showed that tangible interaction is preferred to keyboard interaction and that tangible games are much more enjoyable

    Intra-operative acquisition of sensorimotor fMRI during glioma resection: evaluation of feasibility and clinical applicability

    Get PDF
    Intra-operative fMRI has the potential to improve neurosurgical outcomes and we have previously shown that the task-related BOLD signal can be acquired under general anaesthesia. Our next goal was to acquire fMRI intra-operatively with the skull open. In 12 patients, we performed 24 acquisitions of a passive sensorimotor paradigm during the resection of their brain tumour. The fMRI data were evaluated by neuroradiologists, assessing its applicability for the provision of a clinical report on the location of sensorimotor activation to the neurosurgeon. 17/24 acquisitions were scored as useful. We conclude that intra-operative fMRI is feasible and produces clinically useful data

    Improved Measurement of the Form Factors in the Decay Lambda_c^+ --> Lambda e^+ nu_e

    Full text link
    Using the CLEO detector at the Cornell Electron Storage Ring, we have studied the distribution of kinematic variables in the decay Lambda_c^+ -> Lambda e^+ nu_e. By performing a four-dimensional maximum likelihood fit, we determine the form factor ratio, R = f_2/f_1 = -0.31 +/- 0.05(stat) +/- 0.04(syst), the pole mass, M_{pole} = (2.21 +/- 0.08(stat) +/- 0.14(syst)) GeV/c^2, and the decay asymmetry parameter of the Lambda_c, alpha_{Lambda_c} = -0.86 +/- 0.03(stat) +/- 0.02(syst), for = 0.67 (GeV/c^2)^2. We compare the angular distributions of the Lambda_c^+ and Lambda_c^- and find no evidence for CP-violation: A_{Lambda_c} = (alpha_{Lambda_c^+} + alpha_{Lambda_c^-})/ (alpha_{Lambda_c^+} - alpha_{Lambda_c^-}) = 0.00 +/- 0.03(stat) +/- 0.01(syst) +/- 0.02, where the third error is from the uncertainty in the world average of the CP-violating parameter, A_{Lambda}, for Lambda -> p pi^-.Comment: 8 pages postscript,also available through http://www.lns.cornell.edu/public/CLNS/2004/, submitted to PR

    Branching Fractions of tau Leptons to Three Charged Hadrons

    Full text link
    From electron-positron collision data collected with the CLEO detector operating at CESR near \sqrt{s}=10.6 GeV, improved measurements of the branching fractions for tau decays into three explicitly identified hadrons and a neutrino are presented as {\cal B}(\tau^-\to\pi^-\pi^+\pi^-\nu_\tau)=(9.13\pm0.05\pm0.46)%, {\cal B}(\tau^-\to K^-\pi^+\pi^-\nu_\tau)=(3.84\pm0.14\pm0.38)\times10^{-3}, {\cal B}(\tau^-\to K^-K^+\pi^-\nu_\tau)=(1.55\pm0.06\pm0.09)\times10^{-3}, and {\cal B}(\tau^-\to K^-K^+K^-\nu_\tau)<3.7\times10^{-5} at 90% C.L., where the uncertainties are statistical and systematic, respectively.Comment: 10 pages postscript, also available through http://w4.lns.cornell.edu/public/CLNS, to appear in Phys. Rev. Let

    Observation of the Hadronic Transitions Chi_{b 1,2}(2P) -> omega Upsilon(1S)

    Full text link
    The CLEO Collaboration has observed the first hadronic transition among bottomonium (b bbar) states other than the dipion transitions among vector states, Upsilon(nS) -> pi pi Upsilon(mS). In our study of Upsilon(3S) decays, we find a significant signal for Upsilon(3S) -> gamma omega Upsilon(1S) that is consistent with radiative decays Upsilon(3S) -> gamma chi_{b 1,2}(2P), followed by chi_{b 1,2} -> omega Upsilon(1S). The branching ratios we obtain are Br(chi_{b1} -> omega Upsilon(1S) = 1.63 (+0.35 -0.31) (+0.16 -0.15) % and Br(chi_{b2} -> omega Upsilon(1S) = 1.10 (+0.32 -0.28) (+0.11 - 0.10)%, in which the first error is statistical and the second is systematic.Comment: submitted to XXI Intern'l Symp on Lepton and Photon Interact'ns at High Energies, August 2003, Fermila

    Anti-Search for the Glueball Candidate f_J(2220) in Two-Photon Interactions

    Full text link
    Using 13.3 fb^{-1} of e^+e^- data recorded with the CLEO II and CLEO II.V detector configurations at CESR, we have searched for f_J(2220) decays to K^0_{S} K^0_{S} in untagged two-photon interactions. We report an upper limit on the product of the two-photon partial width and the branching fraction, Gamma_gamma gamma cdot B (f_J(2220) to K^0_{S} K^0_{S}) of less than 1.1 eV at the 95% C.L: systematic uncertainties are included. This dataset is four times larger than that used in the previous CLEO publication.Comment: 10 pages postscript, also available through http://w4.lns.cornell.edu/public/CLNS, Submitted to PRD (R
    • …
    corecore